E-Stim Units

(Click on thumbnail to enlarge)

TENS 2000 3 Mode E-Stim Unit
TENS 2000 3 Mode E-Stim Unit

TENS-2000

3 Mode without Timer

Channels: Dual, Isolated between channels
Modes: Burst, Constant, Modulation
Pulse Width: 60 to 250 microseconds, adjustable
Pulse Amplitude (intensity): 0 to 80 mA each channel, adjustable (500 ohm load)
Pulse Frequency: 2 to 150 Hz adjustable
Modulation Mode: Pulse width automatically varies is a cyclical pattern over an interval of nominally 4 seconds
Burst Mode: 7 pulses per burst, 2 bursts per second, 100Hz internal frequency of burst
Battery Life: 70 hour average (alkaline)
Waveform: Modified square wave with zero net direct current

TENS 2500 3 Mode E-Stim Unit
TENS 2500 3 Mode E-Stim Unit

TENS-2500

3 Mode with Timer

Channels: Dual, Isolated between channels
Modes: Burst, Constant, Modulation
Pulse Width: 60 to 250 microseconds, adjustable
Pulse Amplitude (intensity): 0 to 80 mA each channel, adjustable (500 ohm load)
Pulse Frequency: 2 to 150 Hz adjustable Timer: 30 Min, 60 Min, or Constant
Modulation Mode: Pulse width automatically varies is a cyclical pattern over an interval of nominally 4 seconds
Burst Mode: 7 pulses per burst, 2 bursts per second, 100Hz internal frequency of burst
Battery Life: 70 hour average (alkaline)
Waveform: Modified square wave with zero net direct current

TENS 6000 Digital E-Stim Unit
TENS 6000 Digital E-Stim Unit

TENS-6000

Digital TENS with Timer

Channels: Dual
Modes: Burst, Normal, MRW, SD, Bi-Pulse
Pulse Width: 50-300 microseconds, adjustable
Pulse Amplitude (intensity): 0 to 80 mA each channel
Pulse Frequency: Variable, 2-150 Hz
Waveform: Asymmetric biphasic square pulse
Timer: 5 to 90 Min, or constant time
Compliance Timer: 60 sets of operation records, 999 hours record time

Muscle E-Stim Unit
Muscle E-Stim Unit

EMS-5.0

Muscle Stimulator

Channels: Dual, isolated between channels
Waveform: Asymmetrical Bi-Phase square
Pulse Amplitude: Constant current 0 to 80mA each channel, adjustable (500 ohm load)
Pulse Frequency: Adjustable; 5, 30, 100 Hz
Pulse Ramp: Adjustable, 1, 3, 5 seconds
Contraction: Variable control (1 - 30 Sec.)
Relaxation: Variable control (1 - 45 Sec.)
Battery Life: Approx. 70 hours<

EMS Digital E-Stim Unit
EMS Digital E-Stim Unit

EMS-7500

Digital EMS with Timer

Channels: Dual, isolated between channels
Pulse Width: 50-300 microseconds, adjustable
Pulse Rate: 2-120 Hz, adjustable
Pulse Ramp: 1-8 seconds
Pulse Amplitude: 100 mA peak into 500 phm load
Contraction Time: 0 - 90 seconds
Relaxation Time: 2 - 90 seconds
Waveform: Asymmetric biphasic square pulse
Timer: 1 - 60 Min, or continuous

Pulsed Galvanic E-Stim Unit
Pulsed Galvanic E-Stim Unit

PGS-123

Pulsed-Galvanic Stimulator

Channels: Single
Output Mode: Synchronous or Alternation. Alternation mode-LED alternates between green and red color
Pulse Rate: 2-100 Hz
Wave Form: Positive or negative wave form
Pulse Duration: 5 s
IntraPulse Interval: 100 s.

Microcurrent E-Stim Unit
Microcurrent E-Stim Unit

Micro-II

Analog Microcurrent

Channels: Dual
Output Waveform: Modified square DC biphasic pulses of 0.3Hz, 8Hz, and 80Hz changing polarity at intervals of 1 seconds.
Timer: 20, 40 minutes and constant
Frequency: 0.3, 8 and 80Hz
Output Voltage: 12 Volts

^